1、 Equipment composition
Non vacuum microwave thermolysis Experimental equipment It is composed of microwave system, measurement control system, reactor system, a complete set of pyrolysis gas condensation collection system, protective atmosphere control system (nitrogen, argon, etc.), data acquisition and analysis system, etc.
2、 Main technical parameters
1. Input power supply: 3-phase 380V ± 10% 50Hz;
2. Microwave frequency: 2450 MHz ± 50 MHz;
3. Microwave power: 6KW, microwave power is continuously adjustable;
4. Thermal (cracking) temperature: 0~1000 ℃;
5. Microwave cavity structure: double-layer structure design;
6、 Microwave equipment Material: 304 stainless steel;
7. Cooling mode: Magnetron Water cooling, transformer air cooling, can work continuously for 24 hours;
8. Microwave leakage: microwave leakage ≤ 0.5mw/cm2 (national standard ≤ 5mw/cm2), which is only equivalent to the radiation level when using mobile phones. It has its own microwave leakage prevention alarm device and safety lock. When the microwave exceeds the standard, it can automatically or manually cut off the microwave source;
9. Temperature measurement: infrared and thermocouple two-way measurement;
① Infrared non-contact thermometer (when weighing is required); Temperature measurement range: 0~100 ℃, degree: ± 1 ℃;
② Thermocouple contact thermometer (when weighing is not required); Temperature measurement range: 0~1000 ℃, accuracy: ± 1 ℃.
3、 Scope of use
① Coal; ② Biomass; ③ Minerals; ④ Domestic garbage, etc
Can be customized according to customer requirements