Microwave equipment manufacturer
Your current location: home page > News > Technical Information

contact us Contact Us

Hunan Zhongsheng Thermal Energy Technology Co., Ltd

Tel:+86 0730-8868668

Fax:+86 0730-8868669

Xu R: 187 7308 9988

Liu R: 136 0730 7820

Marketing Department I Luo R: 183 7300 5828

Xu R: 137 6275 6713

Week R: 134 8770 5884

Marketing Department II Wang R: 138 7339 8607

                Week R: 139 7520 8350

Email: [email protected]

website: metynotes.cn

Address: Tonghai Road, Yueyang Economic Development Zone, Hunan Province

What does "Exemption" mean in the List of Exemption Management of Hazardous Wastes

2022-02-24 11:18:25
second

          1 )"The whole process is not": the whole process (each management link) is exempted, and there is no need to implement the relevant regulations on hazardous waste environmental management. It should be emphasized that, except for the hazardous waste transfer process under the scenario of "the whole process is not managed according to hazardous waste", and the transfer process of hazardous waste collection and transfer to the centralized storage point under the exemption condition of the collection process, the transfer manifest can not be run, and for the transfer of hazardous waste under other exemption scenarios, the hazardous waste transfer manifest must be run.

 

          two )"Collection process": if the collection exemption conditions specified in the exemption list of the National Catalogue of Hazardous Wastes are met, the collection unit may not need to hold a hazardous waste collection license, and the transfer process of collecting and transferring to the centralized storage point may not run the transfer sheet; The storage and other links after centralized collection are still managed as hazardous waste.

 

          three )"Utilization process": meet the utilization exemption conditions specified in the exemption list of the National Catalogue of Hazardous Wastes, and the utilization enterprise may not need to hold a comprehensive hazardous waste license; It is necessary to run the transfer sheet, and other links such as storage in the utilization enterprise are still managed as hazardous waste.

 

          four )"Landfill process": meet the exemption conditions for landfill (or incineration) disposal specified in the exemption list of the National Catalogue of Hazardous Wastes. Landfill (or incineration) disposal enterprises may not need to hold a comprehensive hazardous waste license, and the pollution control of landfill (or incineration) shall comply with the requirements of the exemption conditions; It is necessary to run the transfer sheet, and other links such as storage in the disposal enterprise are still managed as hazardous waste.

 

          five )"Cement kiln collaborative disposal process does not": meet the exemption conditions for cement kiln collaborative disposal specified in the exemption list of the National Catalogue of Hazardous Wastes, cement enterprises may not need to hold a comprehensive license for hazardous wastes, and pollution control in the collaborative disposal process shall comply with the requirements specified in the exemption conditions; It is necessary to run the transfer sheet, and other links such as storage in the disposal enterprise are still managed as hazardous waste.

 

          six )"Transportation": the means of transportation may not be dangerous goods.

 

           7 "Transfer process": the transport vehicle carrying out transfer activities may not have the qualification of dangerous goods transport; The hazardous waste transfer form may not be operated during the transfer process, but the transfer activities need to be filed afterwards.



appendix

Hazardous Waste Exemption Management List

Description of each column in this directory:

1. "Serial number" refers to the serial number of hazardous wastes listed in this catalog;

2. "Waste category/code" refers to the category or code of hazardous waste listed in this directory;

3. "Hazardous waste" refers to the name of hazardous waste listed in this catalog;

4. "Exemption link" refers to the link that may not be subject to hazardous waste management;

5. "Exemption conditions" refer to the conditions that may not be met for hazardous waste management;

6. "Exemption content" refers to the content that may not be subject to hazardous waste management.

order

number

Waste category/

code

Hazardous waste

Exemptions

link

Exemption clause   piece

Within exemption   Capacity

 

 

 

 

 

 

one

 

 

 

 

 

Household source hazardous waste

Waste drugs and their packaging, waste pesticides and disinfectants and their packaging, waste paint and solvents and their packaging, waste mineral oil and its packaging, waste film and waste image paper, waste fluorescent tubes, waste thermometers, waste sphygmomanometers, waste nickel cadmium batteries and mercury oxide batteries, and electronic hazardous wastes generated in daily life

 

 

All links

 

 

 

Unclassified collection.

 

 

The whole process is not managed as hazardous waste.

 

 

collect

 

 

Classified collection.

 

 

The collection process is not managed as hazardous waste.

 

two

 

193-002-21

 

Chrome containing leather scrap

 

utilize

Used to produce leather, regenerated leather or electrostatic flocking.

The utilization process is not managed as hazardous waste.

 

 

three

 

 

252-014-11

 

 

Coal tar produced by gas purification

 

 

utilize

Meet the Coal Tar Standard

(YB/T5075-2010), and used as raw materials for deep processing to produce naphthalene, washing oil, anthracene oil, etc.

 

 

The utilization process is not managed as hazardous waste.

 

 

four

 

 

772-002-18

 

 

Domestic waste incineration fly ash

 

 

management

Meet the requirements of Article 6.3 in the Standard for Pollution Control of Domestic Waste Landfill (GB16889-2008), and enter the domestic waste landfill for landfill.

 

The landfill process is not managed as hazardous waste.



order

number

Waste category/

code

Hazardous waste

Exemptions

link

Exemption clause   piece

Within exemption   Capacity

 

 

 

four

 

 

 

772-002-18

 

 

 

Domestic waste incineration fly ash

 

 

 

management

Meet the Standard for Pollution Control of Cement Kiln Cooperative Disposal of Solid Wastes

(GB30485-2013 ),

Enter the cement kiln for collaborative disposal.

 

 

The collaborative disposal process of cement kiln is not managed as hazardous waste.

 

 

five

 

 

772-003-18

 

 

Medical waste incineration fly ash

 

 

management

Meet the Pollution Control Standard for Domestic Waste Landfill

(GB16889-2008).

 

 

The landfill process is not managed as hazardous waste.

 

six

 

772-003-18

Waste metal from hazardous waste incineration

 

utilize

 

It is used for metal smelting.

The utilization process is not managed as hazardous waste.

 

 

seven

 

 

900-451-13

 

Waste resin powder after crushing, sorting and recycling of metal in waste copper clad laminate, printed circuit board and circuit board

 

transport

The means of transport shall meet the requirements of rain proof, seepage proof and anti spillage.

 

Do not transport as hazardous waste.

 

management

Enter the domestic waste landfill for landfill.

The disposal process is not managed as hazardous waste.

 

eight

 

900-041-49

 

Waste pesticide packaging

 

collect

Collection of pesticide waste packaging materials scattered by farmers in villages and towns.

 

The collection process is not managed as hazardous waste.

 

nine

 

900-041-49

Waste oily rags and labor protection appliances

All links

Mixed with household garbage.

The whole process is not managed as hazardous waste.

 

 

 

 

 

 

ten

 

 

 

 

 

 

900-042-49

 

 

 

 

 

Environmental emergencies caused by hazardous chemicals and hazardous wastes and wastes generated during their treatment

 

 

 

transfer

With the consent of the competent environmental protection department at or above the county level in the receiving place, the transfer shall be carried out according to the emergency response plan proposed by the competent environmental protection department at or above the county level in the place where the accident occurred.

 

 

 

The transfer process is not managed as hazardous waste.

 

 

management

It shall be disposed of or utilized according to the emergency disposal plan proposed by the local environmental protection competent department at or above the county level in the place where the accident occurred.

 

 

The disposal or utilization process may not be managed as hazardous waste.

 

eleven

 

900-044-49

 

Lead containing glass of cathode ray tube

 

transport

The means of transport shall meet the requirements of rain proof, seepage proof and anti spillage.

Do not transport as hazardous waste.



order

number

Waste category/

code

Hazardous waste

Exemptions

link

Exemption clause   piece

Within exemption   Capacity

 

twelve

 

900-045-49

 

Discarded circuit board

 

transport

The means of transport shall meet the requirements of rain proof, seepage proof and anti spillage.

 

Do not transport as hazardous waste.

 

 

thirteen

 

 

HW01

 

 

Medical waste

 

 

collect

Engaged in the collection of medical waste generated by medical institutions with a total number of beds less than 19 (including 19).

 

 

The collection process is not managed as hazardous waste.

 

 

 

 

 

 

fourteen

 

 

 

 

 

 

831-001-01

 

 

 

 

 

 

Infectious waste

 

 

 

 

 

 

management

According to High Temperature of Medical Waste

Technical Specification for Centralized Steam Treatment Engineering (HJ/T276-2006) or Technical Specification for Centralized Chemical Disinfection Treatment of Medical Waste Engineering (HJ/T228-2006)

Or Technical Specification for Centralized Treatment of Medical Waste by Microwave Disinfection (HJ/T229-2006).

 

 

 

 

When entering the domestic waste landfill for landfill disposal or entering the domestic waste incineration plant for incineration disposal, the disposal process is not managed as hazardous waste.

 

 

 

 

 

 

fifteen

 

 

 

 

 

 

831-002-01

 

 

 

 

 

 

Injurious waste

 

 

 

 

 

 

management

In accordance with the Engineering Technical Specification for Centralized Treatment of Medical Waste by High Temperature Steam (HJ/T276-2006) or the Engineering Technical Specification for Centralized Treatment of Medical Waste by Chemical Disinfection (HJ/T228-2006)

Or Technical Specification for Centralized Treatment of Medical Waste by Microwave Disinfection (HJ/T229-2006).

 

 

 

 

When entering the domestic waste landfill for landfill disposal or entering the domestic waste incineration plant for incineration disposal, the disposal process is not managed as hazardous waste.

 

 

 

 

sixteen

 

 

 

 

831-003-01

 

 

 

Pathological waste (excluding human organs and infectious animal carcasses)

 

 

 

 

management

In accordance with Technical Specifications for Centralized Chemical Disinfection Treatment of Medical Wastes (HJ/T228-2006) or Technical Specifications for Centralized Microwave Disinfection Treatment of Medical Wastes (HJ/T229-2006)

After processing.

 

 

 

It is incinerated in the domestic waste incineration plant, and the disposal process is not managed as hazardous waste.

 


label

Recent browsing:

Related products

Related news

Overall solution for microwave equipment

Tel:+86 0730-8868668

Xu R: 187 7308 9988 (person in charge of technology and marketing)

Liu R: 136 0730 7820

Marketing Department I Luo R183 7300 5828

Xu R: 137 6275 6713

Week R: 134 8770 5884

Marketing Department II Wang R: 138 7339 8607

              Week R: 139 7520 8350

mail box: [email protected]

Address: Tonghai Road, Yueyang Economic Development Zone, Hunan Province